8 Command Reference


See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

# Parameter Description

Range

1 Requested Distance (position-units)

any

2 Requested Speed (position-units/s)

>0

3 Acceleration Rate (position-units/s

2

)

>0

4 Deceleration Rate (position-units/s

2

)

>0

5 Relative To:

Command Position (0)

Actual Position (1)

Target Position (2)

a valid integer as

described

6 Sync Group

0 to 10

Description

This command is identical to the Sync Move Absolute (13), except that the final

Command Position is computed by adding the Requested Distance to the current value

of the quantity specified in the Relative To parameter. The current value is the value at

the time the RMC received the command.
Relative To Options:

Command Position (0)

The final Command Position is computed by adding the Requested Distance to the

current Command Position.

Actual Position (1)

The final Command Position is computed by adding the Requested Distance to the

current Actual Position.

Target Position (2)

The final Command Position is computed by adding the Requested Distance to the

current Target Position.

For more details, see the Sync Move Absolute (13) command.

Status Bits

In Position Bit
When the Target Positions of all axes in the sync group reach their final positions, and the

Actual Position is within the In Position Tolerance window, the In Position Status bit will

be set. This bit indicates that the move is complete and the axis is at position.
Target Generator Bits
The Target Generator bits in the Status Bits register indicate which portion of the move

the axis is currently in. These bits are useful when programming complex motion

sequences.

Target Generator Done bit
This bit indicates that the Target Positions of all axes in the sync group have reached

their final positions. Notice that this bit does not indicate whether the Actual Position has

reached the Requested Position.
Target Generator State A and B bits
B

A Description

0

0

The target generator is complete