RMC70/150 and RMCTools User Manual

supply needs and connector pin-outs or cable color codes, consult your transducer

manufacturers documentation.

Pin-Out

Pin

Function

Reg In+

High-Speed Registration or Home

Input (12 - 24 VDC)

Reg In-
A+

Encoder A Input (5 V differential)

Jumper for

Termination
A-
Quad Cmn Encoder Common
B+

Encoder B Input (5 V differential)

Jumper for

Termination
B-
Case

Connected to RMC Chassis

Encoder Wiring

The Q1 module interfaces only to quadrature encoders with 5 V Differential Line Driver

(RS-422) signals. Single-ended line drivers (TTL) are not supported due to low noise

immunity.
Use twisted pairs and shielded cables for the A and B signals. Always install the

termination jumper to maintain signal integrity. The termination jumper adds a 249Ω

resistor between the + and - inputs.
The Reg input is compatible with signal levels from 12 to 24 V. It draws 2.7 mA max and

turns on when the voltage across the input is greater than 6 V. The polarity is

unimportant.