beautypg.com

Delta RMC151 User Manual

Page 648

background image

RMC70/150 and RMCTools User Manual

Cable Null modem

Protocol Allen-Bradley DF1 Full-Duplex,

with CRC error detection

Settings 38400 baud, 8 data bits, no parity,

1 stop bit, no handshaking

LEDs

Controller LED
This bi-color (red/green) LED has the following states:

State

Description

Steady Off

No power.

Steady Green

RUN Mode

Flashing Green

(Slow)

PROGRAM Mode

Flashing Green

(Fast)

Updating Flash or a controller restart is pending.

Flashing Red

The device is in the loader. This should occur briefly when the

controller is powered up. If this occurs during normal operation,

an error has occurred in the controller and it must be reset.

Cycle power to the RMC70 to reset it.
Causes:

o

Power Interruption

In certain cases, a power interruption to the RMC may

cause it to go into the loader. Even a very short

interruption, such as 20 msec, can cause problems. This

type of interruption cannot be measured with a standard

multimeter. For accurate power supply verification, use

an oscilloscope or similar high-speed monitoring device.

o

Firmware Bug

Certain firmware bugs will cause the RMC to go into the

loader. If this occurs, and power interruptions have

been ruled out, contact Delta Technical support.

Steady Red

Non-Recoverable major fault. That is, the module cannot boot at

all, not even into the loader. The module will likely need to be

shipped back to Delta for repair. Some things to try to get it

into the Loader (to be done at the direction of technical support)

include removing all expansion and axis modules, and setting

the Force to Loader jumper under the axis module.

Net LED
The NET LED is located below the Controller LED on a gray background.

State

Description

Steady Off

The RMC's PROFIBUS channel is not communicating control data

with the PROFIBUS master. See the Troubleshooting PROFIBUS

topic for possible reasons.

Steady Green

The RMC's PROFIBUS channel is properly communicating control

data with the PROFIBUS master.
During normal operation, this LED should be steady with no

flickering.