9 Register Reference

4

%IX0

5

%IX1

6

%IX2

7

%IX3

8

%IX4

9

%IX5

10

%IX6

11

%IX7

12

%IX8

13

%IX9

14

%IX10

15

%IX11

The slot numbering starts with 0 for the left-

most module in the RMC150.
The I/O Monitor also displays the slot number

and I/O number of each I/O point. For example,

the I/O point 4 in slot 3 is displayed as 3.4.

For example, input 4 in slot 0 is:

(32 x 0) + (4) + 4 = 8


For example, input 7 in slot 5 is:

(32 x 5) + (7) + 4 = 171


See the Primary Input Bits Register for details about the register containing the Negative

Limit Input bit.

9.2.2.2.22.3. Limit Input Polarity

Type: Axis Parameter Register Bit Parameter

RMC70 Address: %MDn.9/12, where n = 12 + the axis number

RMC150 Address: %MDn.9/1, where n = 24 + the axis number

System Tag: _Axis[n].PriInputBits.LimitInPol

How to Find: Axes Parameters Pane, All tab: Feedback

Data Type: bit

Range: Active High (0), Active Low (1)

Default Value: Active High (0)

Description

This parameter specifies the polarity of the Positive Limit Input and Negative Limit Input.

It can be set to the following:

Active High

When the input is physically "on" (voltage is applied), the Positive Limit Input is active.

Active Low

When the input is physically "off" (voltage is not applied), the Negative Limit Input is

active.


The Positive Limit Input or Negative Limit Input status bits indicate the state of the

corresponding limit input. For details on voltage levels, see the specifications for the

module the input is located on.
See the Primary Input Bits Register for details about the register containing the Limit

Input Polarity bit.

9.2.2.2.23. Transducer Specific

9.2.2.2.23.1. Feedback Type (MA Modules)

deltamotion.com

923