beautypg.com

Delta RMC151 User Manual

Page 1128

background image

RMC70/150 and RMCTools User Manual

server IP Address

F45:16 23073

D23072 DINT

%MD45.16 DINT

Read Only DHCP Lease Start

(seconds since

powerup)

F45:17 23075

D23074 DINT

%MD45.17 DINT

Read Only DHCP Lease End

(seconds since

powerup)

F45:18 23077

D23076 DINT

%MD21.18 DINT

Read/Write EtherNet/IP Class 1

TTL (time-to-live)

F45:19 23079

D23078 DINT

%MD245.19 DINT

Read/Write EtherNet/IP Class 1

Start of Multicast

Address Block

F45:20 23081

D23080 DINT

%MD45.20 DINT

Read/Write EtherNet/IP Class 1

Size of Multicast

Address Block

F45:21 23083

D23082 DWORD %MD45.21 DWORD Read/Write Ethernet Outgoing

Cyclic I/O Data

Source

F45:22 23085

D23084 DWORD %MD45.22 DWORD Read/Write Ethernet Incoming

Cyclic I/O Data

Destination

F45:23 23087

D23086 DWORD %MD45.23 DWORD Read Only Controlling

Connection Status

F45:24 23089

D23088 DINT

%MD45.24 DINT

Read Only Controlling PLC

Status

F45:25 23091

D23090 DINT

%MD45.25 DINT

Read/Write Ethernet App Flags

Bits 0-3 - I/O

Data Mode
0=Use a Sync

Register
1=Do not use a

Sync Register
Applies to both

EtherNet/IP and

PROFINET.

Bits 4 - 5 -

PROFINET Byte

Order
0=MSB first
1=LSB first
Applies to

PROFINET.

F45:26-

55

23093-
23151

D23092-
D23150

-

%MD45.26-

55

-

-

Reserved

F45:56-

115

23153-
23271

D23152-
D23270

DWORD %MD45.56-

115

DWORD Read/Write PROFINET Device

Name
Each register in this

range holds four

1108

Delta Computer Systems, Inc.

This manual is related to the following products: