Delta RMC151 User Manual
Page 192
RMC70/150 and RMCTools User Manual
Tip:
In order to use the plot data, you will probably need to know the sample period. The Sample
Period register contains that information.
Registers
The following registers are used in the methods above. The addresses are given here.
#
Register
Name
Details
RMC70
Address
(n= plot #)
RMC150
Address
(n= plot #)
Data
Type
Plot Status/Configuration Registers
Plot Sample
Period
%MD(32+n).2
%MD(96+n).2
REAL
Plot ID
%MD(32+n).8
%MD(96+n).8
REAL
Plot State
0 = not
triggered
1 = capturing
2 = complete
%MD(32+n).9
%MD(96+n).9
REAL
Captured
Samples
%MD(32+n).10 %MD(96+n).10
REAL
Dynamic Plot Upload Registers
0
Upload
Mode/Status
Bits 0-3:
Upload Mode
1 = triggered
2 =
continuous
3 =
continuous,
always newest
Bits 4-7:
Upload Status
0 = normal
1 = plot state
mismatches
upload mode
2 = data
overran (mode
2 only)
%MD(40+n).0
%MD(104+n).0
UDINT
1
Requested
Read
Samples
This is the
number of
samples per
data set.
%MD(40+n).1
%MD(104+n).1
UDINT
2
Current
Index
%MD(40+n).2
%MD(104+n).2
UDINT
3
Plot ID
%MD(40+n).3
%MD(104+n).3
UDINT
4
Samples
Uploaded
The number of
samples read
per data set
%MD(40+n).4
%MD(104+n).4
UDINT
5+ Plot Data
%MD(40+n).5-
4095
%MD(104+n).5-
4095
*
172
Delta Computer Systems, Inc.