beautypg.com

Command: arm registration (52), Arm registration (52) – Delta RMC151 User Manual

Page 847

background image

8 Command Reference

Firmware Requirement: 1.45 or newer

See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

This command has no command parameters.

Description

This command disarms the home, if it was armed. This command clears the Home Armed

status bit.
See the Homing topic for details on homing.

8.7.3. Command: Arm Registration (52)

Supported Axes: Quadrature

Firmware Requirement: 1.45 or newer

See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

# Parameter Description

Range

1 Registration Number

0 or 1

2 Registration Input:

#

RMC70

RMC150

Q1

Input

QAx Input

Quad Input

UI/O Quad

Input

0

Reg

RegX/PosLim

RegX/PosLim

R0

1

n/a

RegY/NegLim

RegY/NegLim

R1

0 or 1

3 Input Edge: Falling (0), Rising(1)

0 or 1

Description

This command enables a position registration to occur on the specified input on the

specified edge. The Registration Number parameter specifies which registration this will

apply to, either 0 or 1.
When this command is issued the following will occur:

The armed status bit of the selected Registration Number (0 or 1) will be set

(Registration 0 Armed or Registration 1 Armed).

The latched status bit of the selected Registration Number (0 or 1) will be cleared

(Registration 0 Latched or Registration 1 Latched).


If the registration is armed and a registration event occurs, the exact position at the

registration event will be latched and recorded in the Registration 0 Position or

Registration 1 Position status register.
For details on registration, see the Registration topic.

deltamotion.com