beautypg.com

Rmc75p cpu module, Rmc75p – Delta RMC151 User Manual

Page 647

background image

7 Hardware

Receive LED

This LED reflects when data is being received on the second serial port (RS-

232/485).

State

Description

Steady Off

No power or no data being received.

Steady or Flickering Green Data is being received.


Note:

The Monitor Port does not affect any LEDs on the RMC70.


7.2.3.4. RMC75P CPU Module

PROFIBUS is a vendor-independent, open fieldbus standard for a wide range of applications in

manufacturing and factory automation. This high-speed fieldbus was designed especially for

communicating between programmable controllers and distributed I/O such as the RMC70

series motion controller.
Up to 126 nodes can be connected to a single network spanning up to 14km. The RMC75P

module supports data rates up to 12Mbaud, permitting high-speed on-the-fly downloads of

positions and parameters to the RMC module and high-speed uploads of motion profile and

status information to the host controller. The RMC75P’s PROFIBUS interface gives the

flexibility of several operating modes. Select the mode that best fits your application and

PROFIBUS master’s capabilities.

Features

One PROFIBUS port

One serial RS-232 Monitor Port

2 rotary switches to set the PROFIBUS station address.

Part Number

The part numbers of the RMC75P is RMC75P. Like all RMC70-series CPU modules, the

RMC75P can only be ordered with an axis module.
For example, RMC75P-MA2 is an RMC75P with a two-axis MA2 module.

Specifications

PROFIBUS-DP Interface

Data Rate 9.6 kbaud up to 12 Mbaud

Isolation 2500 VAC

Product Identifier

Number

0x07E1

Features Supported Sync Mode, Freeze Mode, Auto-baud rate detect

Valid Station

Addresses

0-99 (set by rotary switches on faceplate)

Connector Standard PROFIBUS-DP DB-9 (use termination in cable connectors as per

PROFIBUS specification)

RS-232 Monitor Port

Connector DB-9 Male

deltamotion.com

627

This manual is related to the following products: