beautypg.com

Delta RMC151 User Manual

Page 707

background image

8 Command Reference

This is a complete list of the commands currently available on the RMC, grouped by type. Each

command is represented by an integer number in floating point format. This number is given

in parentheses. For general command information, see the Command topic.
Immediate Commands
Certain commands in the RMC are immediate commands. There is no limit to the number of

immediate commands that can be issued to an axis per loop time, whereas a maximum of one

non-immediate command per loop time can be issued to each axis.
Immediate commands are usually not motion commands. The ability to issue multiple

immediate commands in one loop time affects primarily the user programs, since it is difficult

to issue many simultaneous commands via the external communications.
Command List
Command

Immediate Closed

Loop

Open

Loop

General
No-op (0)

Clear Faults (4)

Enable Controller (7)

Fault Controller (8)

Set Enable Output (67)

Enable/Disable Axis (97)

RUN Mode (98)

PROGRAM Mode (99)

Motion - Stops
Stop (Closed Loop) (6)

Stop (Open Loop) (22)

Hold Current Position (5)

Closed Loop Halt (1)

Open Loop Halt (2)

Direct Output Halt (3)

Motion - Open Loop
Direct Output (9)

Open Loop Rate (10)

Open Loop Absolute (11)

Open Loop Relative (12)

Motion - Synchronized
Sync Move Absolute (13)

Sync Move Relative (14)

Sync Stop (17)

Motion - Point-to-Point
Move Absolute (20)

Move Relative (21)

Quick Move Absolute (15)

Quick Move Relative (16)

Time Move Absolute (23)

deltamotion.com

687

This manual is related to the following products: