17

Axis 1 Select

16

Axis 0 Select

8-15

Reserved

7-0

Command Number

1

Float

Command Parameter 1

2

Float

Command Parameter 2

3

Float

Command Parameter 3

4

Float

Command Parameter 4

5

Float

Command Parameter 5

Data Channel 0:

Registers 6 and 7 are used for reading and writing to any register in

the RMC70. See Read any Single RMC70 Register and Write to

any Single RMC70 Register for details on using these registers.

6

Integer Read/Write Register

Bit

Bit Description

31

Read/Write

30

Read/Write Request

16-29 Reserved
15-8

R/W Address File

7-0

R/W Address Element

7

Float*

Explicit Write Value

Data Channel 1:

Registers 8-15 are used for explicit reads and writes. See Read Any

Contiguous RMC70 Registers and Write Any Contiguous

RMC70 Registers below.

8

Integer Read/Write Command Register

Bit

Bit Description

31

Read/Write

30

Read/Write Request

24-29 Reserved
16-23 Count
15-8

R/W Address File

7-0

R/W Address Element

9

Float*

Explicit Write Value 0

10

Float*

Explicit Write Value 1

11

Float*

Explicit Write Value 2

12

Float*

Explicit Write Value 3

13

Float*

Explicit Write Value 4

14

Float*

Explicit Write Value 5

15

Float*

Explicit Write Value 6

deltamotion.com