Delta RMC151 User Manual
Page 1103
9 Register Reference
loops since
controller startup
(low 24 bits). Only
applies for Plot
State > 0.
F38:12
19481
D19480 REAL
%MD38.12 DINT
Read Only Plot Trigger Time
Time that plot
trigger occurred. In
control loops since
controller startup
(low 24 bits). Only
applies for Plot
State > 0.
F38:13
19483
D19482 REAL
%MD38.13 DINT
Read Only Plot Trigger Index
Index of the plot
sample at which the
plot trigger
occurred. Only
applies for Plot
State > 0.
F38:14-
15
19485-
19487
D19484-
D19486
-
%MD38.14-
15
-
-
Reserved
F38:16-
31
19489-
19519
D19488-
D19518
REAL
%MD38.16-
31
DWORD Read/Write Plot Data Sets 0-15
Addresses
Files %MDn:16-31
contain the
Addresses for plot
Data Sets 0-15.
Bits 0-11 Element
Bits 12-23 File
Plot 7
F39:0
19969
D19968 REAL
%MD39.0 UDINT not
directly
Plot Flags
These bits should
not be accessed
directly.
0 Reserved (Write
Only)
1 Trigger (Write
only)
2 Rearm (Write
Only)
3 Read Active
(Read Only)
4 Trigger Enabled
(Read Only)
F39:1
19971
D19970 REAL
%MD39.1 UDINT Read/Write Plot Samples (e.g.
1000)
F39:2
19973
D19972 REAL
%MD39.2 REAL
Read/Write Plot Sample Period
(seconds)
F39:3
19975
D19974 REAL
%MD39.3 DINT
Read/Write Plot Axis Owner
deltamotion.com
1083