beautypg.com

Programming security – Delta RMC151 User Manual

Page 318

background image

RMC70/150 and RMCTools User Manual

RMC75P

(2.1F or

newer)

3.31.0+

3000µs

1000µs 500µs/250µs

(note 3)

210 µs

(note 1)

--

RMC75P

(2.1E or

older)

3.31.0+ 3000µs/2500µs

(note 4)

1000µs/600µs

(note 5)

250µs

(note 1)

--

--


Note 1: These loop times are only supported in certain controller configurations. See

the loop time topic for details.
Note 2: If the RMC150 has 3 or fewer axes with any number of reference axes, or 4

control axes with up to 2 reference axes, 500µs is allocated. Otherwise 400µs is

allocated.
Note 3: If the RMC75S/RMC75P has 1 control axis with up to 3 reference axes, or 2

control axes with no reference axes, 500µs is allocated. Otherwise, 250µs is allocated.
Note 4: If the RMC75P has 1 control axis with up to 1 reference axes, 3000µs is

allocated. Otherwise, 2500µs is allocated.
Note 5: If the RMC75P has 1 control axis with up to 1 reference axes, 1000µs is

allocated. Otherwise, 600µs is allocated.

5.9. Programming Security

Programming Security is intended to be a means of password-protecting your intellectual

property. If you wish to prevent others from accessing the user programs you write, you can

enable the Programming Security feature.
Delta reserves the right to disable or bypass security features enabled by the copyright holder

of user programming in RMC series controllers. Delta’s responsive customer support is an

important service that benefits the customers. In order to ensure responsive service, Delta

reserves the right to disable or bypass any and all security features applied to the user

programming downloaded to an RMC series controller. For details on when and how Delta will

do this, refer to the RMCTools Security Policy and Agreement.
The Programming Security applies to the items in the Programming node of the Project

Pane. The protection can be applied to an online or offline project. When password-protected

programming is downloaded to the RMC, it will be protected in the RMC also. This means that

when a password-protected project is uploaded from the RMC, the programming will be

protected as specified in the original project.
RMCTools offers three levels of User Source Code Security:

1. Copyright Notice

This level will apply a copyright notice to the Programming. The contents of the

Programming node will still be accessible and editable, but the copyright notice will

appear to the user. Copying and exporting of user programs will be disabled. By

entering the password, the user can disable the copyright notice.

2. Protect Programming Source Code

This level will password-protect the contents of the Programming node in the project.

The programming contents can only be viewed or edited if the user enters the correct

password. The programming contents can be uploaded to an RMCTools project, but

cannot be viewed or edited unless the correct password is entered.

3. Copy Protection

In addition to password-protecting the programming, this level will prevent the

programming from being uploaded to an RMCTools project, thereby preventing the

project from being copied from one controller to another. Copy Protection also

298

Delta Computer Systems, Inc.

This manual is related to the following products: