beautypg.com

Delta RMC151 User Manual

Page 816

background image

RMC70/150 and RMCTools User Manual

command with an S-Curve Ramp Type. The axis will transition to pressure control and go

to the Requested Pressure/Force of 5000.


The plot below shows the transition:

At the beginning of the plot, the position is increasing. At 0.18 seconds, the Actual

Pressure starts increasing. When the Actual Pressure reaches 1000 at approximately 0.2

seconds, the Enter Pressure/Force Control command is issued, the axis transitions to

pressure control, and then the Target Pressure ramps to 5000.
Exiting Pressure/Force Control
To exit pressure/force control, send any open-loop command or closed-loop position

command to the axis.

Status Bits

At Pressure/Force
When the axis is in Pressure or Force control and the Target Pressure or Force reaches

the Requested Pressure/Force and the Actual Pressure or Actual Force is within the At

Pressure/Force Tolerance window from the Target Pressure/Force, the At Pressure/Force

Status bit will be set. This bit indicates that the ramp is complete and the axis is at the

pressure or force.
Pressure/Force Control
The Pressure/Force Control Status bit indicates that the axis is in closed-loop pressure or

force control.
Pressure/Force Target Generator Bits

The Pressure/Force Target Generator bits in the Status Bits register indicate which

portion of the move the axis is currently in. These bits are useful when programming

complex motion sequences.

796

Delta Computer Systems, Inc.

This manual is related to the following products: