The Options dialog contains various RMCTools settings. These settings apply to RMCTools, and

are not saved to the project file or the RMC controller. The Options dialog contains the

following sections:

Environment Page

Startup
Choose what happens when RMCTools starts up.
Address Format
This applies to windows that show register addresses, such as the Axis Tools, Indirect Data

Map Editor, and Variable Table Editor. This only affects how the register addresses are

displayed.
If you are using a PLC or HMI to communicate with the RMC, setting this to the addressing

method you are using makes it easy to find addresses for registers in the RMC. You can

also set the address format by right-clicking any Register cell in RMCTools and choosing

Address Format.
Output Window
Check this box to automatically close the Output window after a successful Upload All or

Download All, unless it was previously open.

Programming Page

Program Timing
When RMCTools verifies the Programming, it displays the results in the Verify Results

window. This option specifies how much detail is shown in the Verify Results window. For

more details, see the Program Capacity and Time Usage topic.
Verify Results
Check this box to automatically close the Verify Results window after a successful verify,

unless it was previously open.

Step Editor
Select whether to show the tag browser when editing expression in the expression editor.

Communications Page

Communication Log

Choose how much information is saved in the Communication Log. This option should only

be changed when directed by Delta technical support.

Firmware Update

Specify the communication rate at which the firmware download to the RMC75S and

RMC75P occurs. Higher baud rates will mean quicker firmware updates. The default baud

rate is 115200, and should be supported by most PCs. If you have trouble with this baud

rate, you should try selecting 38400. Baud rates above 115200 are generally only

supported on specialized serial ports.

USB/Serial Timeouts

This section specifies the timeouts used for DF1 communciation via the RMC75P monitor

port, the RMC75S monitor port and comm port, and the RMC75E USB monitor port. The

timeouts can be adjusted to accommodate a poor serial connection.
Ethernet Timeouts
If you are connected to the RMC via Ethernet and are experiencing lost connections, you

can adjust the Ethernet timeouts to accommodate the unreliable connection. Several

preset profiles are available, or you can choose custom to set your own timeouts:

Default: This setting works for most LANs (Local Area Networks) and Internet

connections.

LAN: This setting is optimized for LAN connections.