Delta RMC151 User Manual
Page 1093
9 Register Reference
Bits 12-23 File
Plot 1
F33:0
16897
D16896 REAL
%MD33.0 UDINT not
directly
Plot Flags
These bits should
not be accessed
directly.
0 Reserved (Write
Only)
1 Trigger (Write
only)
2 Rearm (Write
Only)
3 Read Active
(Read Only)
4 Trigger Enabled
(Read Only)
F33:1
16899
D16898 REAL
%MD33.1 UDINT Read/Write Plot Samples (e.g.
1000)
F33:2
16901
D16900 REAL
%MD33.2 REAL
Read/Write Plot Sample Period
(seconds)
F33:3
16903
D16902 REAL
%MD33.3 DINT
Read/Write Plot Axis Owner
0-3, -1 = none
F33:4
16905
D16904 REAL
%MD33.4 REAL
Read/Write Plot Trigger Position
%, 0-100, -1 =
auto rearm
F33:5
16907
D16906 REAL
%MD33.5 UDINT Read/Write Plot Trigger Type
0-
7
Trigger Type
(0=none,
1=motion
command)
8-
23
Depends on
trigger type
Motion
Commands:
8-
11
Axis 0-3 bits,
if all zero,
then use
Axis Owner
12-
23
Reserved
F33:6
16909
D16908 REAL
%MD33.6
-
-
Reserved
F33:7
16911
D16910 REAL
%MD33.7
-
-
Reserved
F33:8
16913
D16912 REAL
%MD33.8 REAL
Read Only Plot ID
F33:9
16915
D16914 REAL
%MD33.9 REAL
Read Only Plot State
0 = not triggered, 1
= capturing, 2 =
deltamotion.com
1073