beautypg.com

Delta RMC151 User Manual

Page 942

background image

RMC70/150 and RMCTools User Manual

System Tag: _Axis[n].PriInputBits.NegLimitIn

How to Find: Axes Parameters Pane, All tab: Feedback

Data Type: bits

Default Value: 0 (none)

Description

Each RMC axis allows for optional physical limit inputs to specify the boundaries in which

the axis is allowed to operate. Each axis can have two physical limit inputs: Positive Limit

Input and Negative Limit Input. Typically, these inputs are wired to limit switches.
The physical limit inputs differ from the Travel Limits, which limit the range of travel of an

axis based on the feedback (position, pressure, etc.). The Travel Limits are required to be

set on an axis; physical limit inputs are optional.
The Negative Limit Input bit parameter selects which discrete input, if any, should be

used as a 'Negative Limit Input'. For details on physical limit inputs, and the options of

this parameter, see the Physical Limit Inputs topic.
In RMCTools, this parameter will allow you choose an input from the drop-down box.

Inputs will be listed by their address. Use the Discrete I/O Configuration editor to find the

addresses of inputs.
The following options are possible:

Option

Description

none

This is the default setting.

Fault

Input

RMC70: The Fault Input of the axis.
RMC150: The Fault Input of the axis. Only available

on the Quadrature Module.

Dedicated Available on RMC70 QA and RMC150 Quadrature

modules only. This is the NegLim input on the

module.

general

input

RMC70: any input from a D8 module, but only from

the first 12 I/O points as listed in the I/O Monitor.
RMC150: any general discrete input from any

module.

Negative Limit Format Details

This section is primarily for addressing the Negative Limit Input parameter when

communicating with the RMC from an external device. This information is not necessary

when configuring the Negative Limit Input in RMCTools.
The Negative Limit Input is selected with bits in the Primary Input Bits register, as shown

in the following table:

RMC70

Value

of
bits 8-

11

Negative Limit

Input

0

none

1

Fault Input

2

Dedicated

(RegY/NegLim)

3

-

RMC150

Value of bits 16-23

Negative Limit

Input

0

none

1

Fault Input

2

Dedicated

(RegY/NegLim)

3

-

(32 x slot) + (i/o point) + 4 %IXslot.(i/o point)

922

Delta Computer Systems, Inc.

This manual is related to the following products: