beautypg.com

Delta RMC151 User Manual

Page 660

background image

RMC70/150 and RMCTools User Manual

The 2-axis Analog Pressure expansion module (AP2) is one of the optional expansion modules

available for the RMC70 series motion controller. This module provides two analog inputs with

16-bit resolution and support for position-pressure and position-force control.
The AP2 should not be confused with the A2, which provides analog input and no support for

secondary pressure control. The RMC70 always requires an AP2 module for position-pressure

or position-force control.
Note: Using the AP2 module, it is possible to add more analog inputs on the RMC70 than can

be assigned to axes. However, it is still possible to view the voltage of the extra analog inputs

using the Analog Input Registers. Inputs that are unassigned to axes can have no status bits,

error bits, scaling, filtering, etc.

Features

Two 16-bit voltage or current inputs - each individually selectable

±10 V and 4-20 mA input ranges

8 times oversampling

Part Number

The part number of the AP2 module is EXP70-AP2.

Uses

The AP2 is useful for the following purposes:

Dual-loop Control

The AP2 pressure or force inputs can be used in conjunction with the position or

velocity control from an RMC7x axis module to provide the following combinations

of dual-loop control:

o

Position-Pressure or Position-Force

o

Position-Acceleration (advanced)

o

Velocity-Pressure or Velocity-Force

o

Velocity-Acceleration (advanced)

Pressure/Force Control

The AP2 inputs, configured for pressure or force, can be used in conjunction with an

output on an RMC70 axis module for solely pressure or force control. The RMC70

always requires an AP2 module for dual-loop. See the Position-Pressure and

Position-Force Control and Position-Acceleration topics for more details.

Analog Reference Input

Reference inputs are often used as gearing or camming masters. Reference inputs

cannot be used for direct control of the input axis. If the application requires a

position input and not a pressure or force input, the A2 Expansion module is a

better choice.

Specifications

Analog Interface

Inputs Two 16-bit differential

Isolation 500 VAC

Overvoltage protection ±40 V

Input ranges ±10 V and 4 20 mA (each channel independently configured)

Input impedance Voltage Input: 5 MΩ

Current Input: 250 Ω

Input filter slew rate 25 V/ms

Oversampling 8 times per control loop

640

Delta Computer Systems, Inc.

This manual is related to the following products: