7 Hardware

Part Number

The part number of the PROFIBUS module is -PROFI. The PROFIBUS module fits only in

the left-most slot of the RMC backplane.
For example, RMC150E-S1-PROFI is an RMC150E with an SSI module and a PROFIBUS

module. RMC150E-S3-Q1-PROFI is an RMC150E with three SSI modules, one Quadrature

module, and a PROFIBUS module.

Specifications

For general specifications on the RMC150, see the RMC150 Overview topic.

PROFIBUS-DP Interface

Data Rate 9.6 kbaud up to 12 Mbaud

Isolation 2500 VAC

Product Identifier

Number

0x0AC6

Features Supported Sync Mode, Freeze Mode, Auto-baud rate detect

Valid Station

Addresses

0-126 (set by software or Set Slave Address function)

Connector Standard PROFIBUS-DP DB-9 (use termination in cable connectors as per

PROFIBUS specification)

LEDS

Comm Status

State

Description

Steady

Off

No PROFIBUS connection is established. See the Troubleshooting PROFIBUS

topic for possible reasons.

Steady

Green

A PROFIBUS connection is established.

Note:

These are the only two LED states of the NET LED, but it is possible to have the Net LED

flashing or flickering green, which indicates that the RMC75P is going on- and off-line on

the PROFIBUS channel and generally indicates a network or configuration problem.

7.4. General

7.4.1. Control Output

The Control Output is the control signal voltage supplied by the RMC to drive the amplifier,

valve, or drive for the system to be controlled. It is an analog output with a voltage range of -

10 V to + 10 V. To convert the Control Output to current, use Delta's VC2124 voltage-to-

current converter.
The modules listed below have a Control Output. The Control Output is labeled Drive or Drv

on the RMC150 modules.