RMC70/150 and RMCTools User Manual

10. The final module configuration will look similar to the following:

Take note of the input (I) starting address (256 in the above example), and output (Q)

starting address (256 in the above example). These are required for accessing the IO

data as described below. Also, the Diagnostic address for slot 0 (2043 in the above

example) is used when reading and writing record data, as described below.

11. Save and download the configuration to your S7 controller.

Using the Cyclic I/O Data in the S7

The first step in using cyclic I/O data in the S7 is to define a data block (DB) for each of

the Input Data and Output Data. The structure of the Input and Output DBs should match

the data defined in the RMC for the Outgoing and Incoming Cyclic I/O Data respectively:

604

Delta Computer Systems, Inc.