beautypg.com

Delta RMC151 User Manual

Page 437

background image

6 Communication

Data registers in the response. Notice that the Packet

Length byte order is not affected by this field.

Least-Significant Byte (LSB) First (00). For

example, the value 0x1122 will be encoded as 22

11.

Most-Significant Byte (MSB) First (01). For

example, the value 0x1122 will be encoded as 11

22.

8-9

nn nn

Starting Address (File). Gives the file number (f)

for the address (%MDf.e) to start the read at. The

order of the bytes in this 16-bit value is determined

by the Byte Order field.

10-11 nn nn

Starting Address (Element). Gives the element

number (e) for the address (%MDf.e) to start the

read at. The order of the bytes in this 16-bit value is

determined by the Byte Order field.

12-13 nn nn

Read Count. The number of 32-bit registers to read.

This value must be between 0 and 256. The order of

the bytes in this 16-bit value is determined by the

Byte Order field.


The RMC will respond to this request with the following packet:

Offset Data

(hex)

Description

0-1

nn nn

Packet Length. Indicates the total length in bytes of

this packet, excluding this 2-byte field. This 16-bit

value is encoded with the least significant byte first.

2-3

00 02

Static Values. These bytes will always have these

values in the response.

4-5

nn nn

Transaction ID. This value will echo the Transaction

ID in the request. It should be used to match this

response to the corresponding request.

6

94 -or- 54 Function Code (Response). If the read was

processed successfully, this byte will be 94, otherwise

it will hold 54.

7

nn

Response Code. Indicates whether the read was

successful or not. See the DMCP Response Codes

section below.

8-…

Data. The values of each register that was read will

follow the above header. Each 32-bit value is encoded

in either LSB- or MSB-first byte order, as determined

by the Byte Order field. For LSB-first byte order, the

value 16#11223344 will be encoded as 44 33 22 11.

For MSB-first byte order, this will be encoded as 11

22 33 44.

Register Addresses

This protocol uses the RMC’s two-level file/element addressing format. The IEC Addressing

topic describes how this addressing format works.

DMCP Response Codes

deltamotion.com