Ssi clock mode, Ssi termination parameter, Ssi termination – Delta RMC151 User Manual

Page 949: E ssi clock mode, E ssi termination

background image

9 Register Reference

RMC150 UI/O Module

Bit

11

Bit

10

SSI Clock Rate

0

0

250 kHz

0

1

500 kHz

1

0

971 kHz


See the MDT/SSI Configuration Register for details about the register containing these

bits.

9.2.2.2.23.7. SSI Clock Mode

Type: Axis Parameter Register

RMC70 Address: %MDn.10/1, where n = 12 + the axis number

RMC150 Address: %MDn.10/1, where n = 24 + the axis number

System Tag: _Axis[n].MDTSSICfg.SSIMonitor

How to Find: Axes Parameters Pane, All tab: Feedback

Data Type: boolean

Range: standard (0), monitor (1)

Default Value: standard (0)

Description

This parameter is valid on axes with SSI feedback on the UI/O Module. It provides two

options for the clock on an SSI input assigned to an axis:

Standard Mode

In standard mode, the SSI channel sends out a clock signal to the SSI device, and the

SSI device responds with the data. This is the typical behavior when an SSI device is

connected to an RMC.

Monitor Mode

In monitor mode, the SSI channel clock is an input. This mode is used to monitor the

communication between an RMC and an SSI device. This is useful for daisy-chaining

multiple UI/O modules to a single SSI device.

9.2.2.2.23.8. SSI Termination Parameter

Type: Axis Parameter Register

RMC150 Address: %MDn.10/0, where n = 24+ the axis number

System Tag: _Axis[n].MDTSSICfg.SSITerm, where n is the axis number

How to Find: Axes Parameters Pane, All tab: Feedback

Data Type: boolean

Range: none (0), ±Data (1)

Default Value: none (0)

Description