8 Command Reference

frequency is the inverse of the Loop Time). For example, if the loop time is 1000 µsec,

the maximum frequency is 250 Hz.

Loop Time Max Frequency
250 µsec

1000 Hz

500 µsec

500 Hz

1000 µsec

250 Hz

2000 µsec

125 Hz

4000 µsec

62.5 Hz

Fractional frequencies are valid, such as 0.345 or 5.84. Issuing this command with a

frequency of zero is typically only done when it will be followed by the Change Target

Parameter (Prs/Frc) (81) to ramp the frequency from 0 to some value. A frequency of

zero is not allowed if the Start Location is at one of the peaks, and the cycle count is

0.25.
Frequencies below 0.00001 on the RMC75 or RMC150E, and below 0.05 on the RMC75S

and RMC75P, may cause an irregular Target Force/Pressure when used with the Start

Locations Mid-Pos or Mid-Neg. Test any very low frequencies before using them.
Start Location
The Start Location specifies where on the sine wave the motion should start. When this

command is issued, the Target Pressure/Force must be at that location, unless a

Transition command has previously been issued to specify how the axis should move to

get to the sine curve. The Start Location options are given below. Notice that each cycle

will start at the location specified by the Start Location.

Start

Location

Description

Auto

If the Target Pressure or Force is at the positive peak, negative peak, or the

center, then the sine move will start there. If it starts at the center, it will

move in the positive direction. See Mid-Pos and Mid-Neg Details below.

Mid-Pos

The sine wave will start at the center (zero degrees) and move in the positive

direction. See Mid-Pos and Mid-Neg Details below.

Pos Peak The sine wave will start at the positive peak (90 degrees).
Mid-Neg

The sine wave will start at the center (180 degrees) and move in the negative

direction. See Mid-Pos and Mid-Neg Details below.

Neg Peak The sine wave will start at the negative peak (270 degrees).

For example, if the Start Location is Auto, the Offset is 3, and the Amplitude is 1, then

the Target Pressure/Force must be at 2, 3, or 4 when this command is issued. If the

Start Location is Pos Peak, the Offset is 10, and the Amplitude is 2, then the Target

Pressure/Force must be at 12 when this command is issued.
The diagrams below show what the start of the sine wave looks like for a the starting

locations.

Mid-Pos

Mid-Neg

Neg Peak

Pos Peak