7 Hardware

Analog Input Features

Two 16-bit analog inputs, ±10 V or 4-20 mA

Discrete I/O Features

6 I/O, individually configurable as input or output

Inputs: 12 to 24 VDC, sinking (require sourcing driver)

Outputs: Solid state relay, 50 mA continuous

Inputs 0 and 1 can be used as high-speed registration inputs in conjunction with the

quadrature inputs.

High-Speed Channels

Each of the two RS-422 channels are independently configurable as Quadrature or SSI.
Quadrature Channels

A and B quadrature inputs

Requires 5 V differential (RS-422) signals

Discrete inputs 0 and 1 can be used as high-speed registration or homing inputs in

conjunction with quadrature inputs 0 and 1, respectively.

SSI Channels
The SSI channels can be configured to do the following tasks:

Receive SSI Input from a Transducer

This is a standard SSI input for obtaining data from an SSI transducer or encoder.

Monitor SSI Communication on Another Device

The SSI channel can monitor the data that another RMC is receiving from an SSI

device. This makes it possible to synchronize multiple RMCs to one SSI transducer.

Send Data Out Via SSI (Slave)

The SSI channel behaves as a transducer or encoder and will return data to the

requesting master.

Send Data between RMCs

The SSI channels can continuously send any RMC register to an SSI input on another

RMC. This provides communication between RMCs. Notice that only one register can

be transferred between RMCs.

Part Number

The UI/O Module can be placed in slot 0, 2, 3, 4, or 5 of the RMC150 backplane.

However, because the backplane connector of slot 0 (the leftmost slot) is different from

that of slots 2-5, the part number of a UI/O module for slot 0 differs from a UI/O module

for slots 2-5.
If placed in slot 0, the part number is UI/O. If placed in slots 2, 3, 4, or 5, the part

number is Un, where n is the number of U modules. Multiple Universal I/O modules can

be placed in the same rack.

Slot Part Number

0 UI/O

This must be added to the end of the part

number, for example RMC150E-M1-H2-UI/O.

2-5 Un

where n is the number of UI/O modules, for

example RMC150E-M1-U2.

Setting Up UI/O Analog Inputs

1. Wire the analog input as described in the Analog Wiring topic.