beautypg.com

Delta RMC151 User Manual

Page 246

background image

RMC70/150 and RMCTools User Manual


Tuning Parameters
You can change the tuning parameters and then download
them to the controller by clicking the Download button. For

challenging tuning systems, you also have access to all the

axis parameters, just as in the Axes Parameters pane in the

Axis Tools.




Status Registers
This section provides you with basic axis information. For

example, the Actual Position is helpful so you know which

direction to move the axis.
You can choose which registers appear by clicking the
Customize Tuning Tools

button.

Command Buttons
Tuning involves repeatedly issuing the same commands to

move the axis back and forth. The command buttons ([Click

to Set up]) simplify this process. Click the button to customize

it.

Using the Tuning Tools

After you have set up your actuator and feedback, and completed the scale and offset,

you are ready to tune the axis. The following procedure describes how to use the Tuning

Tools to tune your axis.
Autotuning

Position Axes
To autotune a position axis, click Tuning Wizard and follow the wizard. After

completing autotuning, you must test the tuning by moving the axis. Read the

Manual Tuning section below to learn how to set up the command buttons to move

the axis and view plots of the motion.
Pressure or Force Axes
The Tuning Wizard can calculate gains for pressure or force axes given an existing plot

that shows the pressure or force changing. On the Pressure tab, click Tuning

Wizard.

Manual Tuning
This section describes how to use the Tuning Tools during the tuning process. It does not

describe the order of changing gains. For details on which gains to change when during

the tuning procedure, see the Tuning Overview topic.

1. Set Up the Command Buttons

For position axes, click the Position tab. For pressure or force axes, click the Pressure

or Force tab. Then, set up the command buttons so that one button will move the axis

one direction, and the other will move it in the other direction.

a. Click the down arrow on the command button

.

b. Enter the parameters for the command, then click OK.
c. Make sure the correct plot template is selected.

226

Delta Computer Systems, Inc.

This manual is related to the following products: