Delta RMC151 User Manual
Page 1136
RMC70/150 and RMCTools User Manual
Note:
When communicating via a protocol that uses DF1 addressing, the Plot Data can be accessed
with registers 5-4095, if the host controller allows it. Other protocols can only address Plot
Data registers 5-255, as indicated below.
AB
DF1,CSP
Address
Modbus
Address
External
Data
Internal
IEC
Address
Internal
Access
Register Name
Plot 0
F104:0 53249
E0_20480 DINT
%MD104.0 UDINT Read/Write Plot 0 Upload
Mode/Status
F104:1 53251
E0_20482 DINT
%MD104.1 UDINT Read/Write Plot 0 Requested
Read Samples
F104:2 53253
E0_20484 DINT
%MD104.2 UDINT Read/Write Plot 0 Current
Index
F104:3 53255
E0_20486 DINT
%MD104.3 UDINT Read Only Plot 0 Plot ID
F104:4 53257
E0_20488 DINT
%MD104.4 UDINT Read Only Plot 0 Samples
Uploaded
F104:5-
255
53259-
53759
E0_20490-
E0_20990
*
%MD104.5-
255
*
Read Only Plot 0 Data
Plot 1
F105:0 53761
E0_20992 DINT
%MD105.0 UDINT Read/Write Plot 1 Upload
Mode/Status
F105:1 53763
E0_20994 DINT
%MD105.1 UDINT Read/Write Plot 1 Requested
Read Samples
F105:2 53765
E0_20996 DINT
%MD105.2 UDINT Read/Write Plot 1 Current
Index
F105:3 53767
E0_20998 DINT
%MD105.3 UDINT Read Only Plot 1 Plot ID
F105:4 53769
E0_21000 DINT
%MD105.4 UDINT Read Only Plot 1 Samples
Uploaded
F105:5-
255
53771-
54271
E0_21002-
E0_21502
*
%MD105.5-
255
*
Read Only Plot 1 Data
Plot 2
F106:0 54273
E0_21504 DINT
%MD106.0 UDINT Read/Write Plot 2 Upload
Mode/Status
F106:1 54275
E0_21506 DINT
%MD106.1 UDINT Read/Write Plot 2 Requested
Read Samples
F106:2 54277
E0_21508 DINT
%MD106.2 UDINT Read/Write Plot 2 Current
Index
F106:3 54279
E0_21510 DINT
%MD106.3 UDINT Read Only Plot 2 Plot ID
F106:4 54281
E0_21512 DINT
%MD106.4 UDINT Read Only Plot 2 Samples
Uploaded
F106:5-
255
54283-
54783
E0_21514-
E0_22014
*
%MD106.5-
255
*
Read Only Plot 2 Data
Plot 3
F107:0 54785
E0_22016 DINT
%MD107.0 UDINT Read/Write Plot 3 Upload
Mode/Status
1116
Delta Computer Systems, Inc.