Page 938: Channel a offset, Channel b offset, Channel a offset), Channel b offset)

background image

RMC70/150 and RMCTools User Manual

These parameters are used together with the Channel A Force Offset and Channel B Force

Offset parameters to calculate the Actual Force from inputs 0 and 1 of a dual-input

(differential) force axis.
Channel A Force Scale converts the Channel A voltage or current to Fr units. The Channel

A Force Offset is then added resulting in the Channel A Force.
Channel B Force Scale converts the Channel B voltage or current to Fr units. The Channel

B Force Offset is then added resulting in the Channel B Force.
Changing this Parameter
Because this parameter affects motion, the axis must be disabled or in Direct Output

before writing to this parameter. The Enabled and Direct Output Status Bits indicate these

states of the axis. When changing this parameter from RMCTools, the software will

automatically do this for you. This may cause a halt on the axis, which is expected.

9.2.2.2.21.2. Channel A Force Offset, Channel B Force Offset

Type: Axis Parameter Register

RMC70 Address: Channel A Force Offset:

Primary Input: %MDn.1, where n = 12 + the axis number
Secondary Input: %MDn.19, where n = 12 + the axis number

Channel B Force Offset:
Primary Input:
%MDn.3, where n = 12 + the axis number
Secondary Input: %MDn.21, where n = 12 + the axis number

RMC150 Address: Channel A Force Offset:

Primary Input: %MDn.1, where n = 24 + the axis number
Secondary Input: %MDn.19, where n = 24 + the axis number

Channel B Force Offset:
Primary Input:
%MDn.3, where n = 12 + the axis number
Secondary Input: %MDn.21, where n = 24 + the axis number

System Tag: Channel A Force Offset: _Axis[n].FrcAOffset

Channel B Force Offset: _Axis[n].FrcBOffset
where n is the axis number

How to Find: Axes Parameters Pane, Setup tab: Primary Control Setup

Axes Parameters Pane, Setup tab: Secondary Control Setup

Data Type: REAL

Units: Fr

Range: any

Default Value: 0

Description

These parameters are used together with the Channel A Force Scale and Channel B Force

Offset parameters to calculate the Actual Force from inputs 0 and 1 of a dual-input

(differential) force axis.
Channel A Force Offset shifts the Channel A Force.
Channel B Force Offset shifts the Channel B Force.

918