The integer number for output 1 in slot 1 (the CPU

slot) is:
(32 x 1) + 7 = 39

The integer number for output 3 in slot 5 is:
(32 x 5) + 3 = 163

8.9. Plots

8.9.1. Command: Start Plot (100)

Supported Axes: All

Firmware Requirement: 1.00 or newer

See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

# Parameter Description

Range

1 Plot Number

any valid plot

number

Description

This command starts a one-time plot. It erases the plot buffer and starts capturing a plot

until the buffer is full. At that point, it stops capturing and waits until the plot is reset.

Compare this with the Stop Plot (101) and Trigger Plot (102) commands.
To find out more about plotting, see the Using Plots topic.

8.9.2. Command: Stop Plot (101)

Supported Axes: All

Firmware Requirement: 1.00 or newer

See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

# Parameter Description

Range

1 Plot Number

any valid plot

number

Description

836

Delta Computer Systems, Inc.