9 Register Reference

Ff:10

49173 +

b

E0_16404

+ b

REAL

%MDf.10 DINT

Read Only Plot Captured

Samples
Number of plot

samples captured.

Only applies for Plot

State > 0.

Ff:11

49175 +

b

E0_16406

+ b

REAL

%MDf.11 DINT

Read Only Plot Sample 0 Time

Time that first plot

sample was

captured. In control

loops since

controller startup

(low 24 bits). Only

applies for Plot State

> 0.

Ff:12

49177 +

b

E0_16408

+ b

REAL

%MDf.12 DINT

Read Only Plot Trigger Time

Time that plot

trigger occurred. In

control loops since

controller startup

(low 24 bits). Only

applies for Plot State

> 0.

Ff:13

49179 +

b

E0_16410

+ b

REAL

%MDf.13 DINT

Read Only Plot Trigger Index

Index of the plot

sample at which the

plot trigger

occurred. Only

applies for Plot State

> 0.

Ff:14-
15

49181 +

b
49183 +

b

E0_16412

+ b
E0_16414

+ b

-

%MDf.14-

15

-

-

Reserved

Ff:16-
31

49185 +

b
49215 +

b

E0_16416

+ b
E0_16446

+ b

REAL

%MDf.16-

31

DWORD Read/Write Plot Data Sets 0-15

Addresses
Files %MDn:16-31

contain the

Addresses for plot

Data Sets 0-15.
Bits 0-11 Element
Bits 12-23 File

RMC150 Registers, Files 104-111: Dynamic Plot Upload Area Registers

The following files contain the Dynamic Plot Upload Area registers. See the Reading Plots with

a Host Controller topic for details on how to use them.
Tip:

For the DF1/CSP addressing format, all 'F' type registers (32-bit floating point) can also be

read as 'L' type (32-bit word) registers. This is very useful when reading data of DWORD or

DINT external data types.