Delta RMC151 User Manual
Page 1046
RMC70/150 and RMCTools User Manual
1=B, etc.)
Bits 8-15: Minor Revision
Bits 16-23: Major Revision
Bits 24-31: Reserved
For example, 2.1E will be
0x00020104.
F7:32
3649
D03648 REAL
%MD7.32
DINT
Firmware Patch Number
Holds the patch level of the
firmware version. For example,
for 3.30.0, this value will be 0,
and for 3.30.1, it will be 1.
RMC70 Registers, Files 8-11: Axis Status Registers
All Axis Status Registers are Read Only.
Axis 0
AB
DF1,CSP
Address
Modbus
Address
External
Data
Internal
IEC
Address
Internal
Register Name
Common Registers: All Axes
F8:0
4097
D04096 DWORD %MD8.0
DWORD Status Bits
F8:1
4099
D04098 DWORD %MD8.1
DWORD Error Bits
F8:2
4101
D04100 REAL
%MD8.2
DINT
F8:4
4105
D04104 REAL
%MD8.4
REAL
Position/Velocity Control
F8:6
4109
D04108 REAL
%MD8.6
DINT
F8:7
4111
D04110 REAL
%MD8.7
DINT
Primary Input: Position/Velocity Axes
F8:8
4113
D04112 REAL
%MD8.8
REAL
F8:9
4115
D04114 REAL
%MD8.9
REAL
F8:10
4117
D04116 REAL
%MD8.10 REAL
F8:11
4119
D04118 REAL
%MD8.11 REAL
F8:12
4121
D04120 DINT
%MD8.12 DINT
Primary Input: Single-Input Pressure, Force, or Acceleration Axes
F8:8
4113
D04112 REAL
%MD8.8
REAL
F8:9
4115
D04114 REAL
%MD8.9
REAL
F8:11
4119
D04118 REAL
%MD8.11 REAL
F8:12
4121
D04120 DINT
%MD8.12 DINT
Primary Input: Dual-Input Force or Acceleration Axes
F8:8
4113
D04112 REAL
%MD8.8
REAL
Actual Differential Force, Actual
1026
Delta Computer Systems, Inc.