Using custom plots – Delta RMC151 User Manual

Page 241

background image

4 Using RMCTools

Plot template sets are for advanced usage, can be confusing, and are hidden by default.

You will likely never need to use them.
All the plot templates together are called a plot template set. Normally, the RMC has

only one plot template set, but you can create multiple plot template sets, of which one

can be active at a time.
See Using Plot Template Sets for more details.

4.9.4. Using Custom Plots

Each individual plot in a plot template can be set as either a Default or Custom plot. Default

plots are managed by RMCTools and cannot be edited. RMCTools will automatically determine

which registers should be plotted and how they are displayed, based on the axis type. In order

to change items in an individual plot template, such as plotted registers and pen color, the plot

must be set to Custom Plot.
To set a plot to Custom:

1. Open the Plot Template Editor.
2. In the Individual Settings area, on the desired plot tab, choose Custom Plot.

Changing a Custom Plot

To edit the plot templates, make the desired changes in the Plot Template Editor, then

click the Download button in the Plot Template Editor toolbar. Update Flash to retain this

plot set in the controller even after power is removed from the controller.
Any changes made to a plot in the Plot Template Editor will apply to all subsequent plots

uploaded in the Plot Manager for the selected plot template.

Adding and Removing Plot Quantities

Adding a Plot Quantity

1. Click New Quantity.
2. In the Plot Quantity Selection Tool, browse to the register you need, then click Add or

press the space bar. Repeat to quickly add consecutive registers. Use the Groups tab

to quickly add the basic status registers or tuning terms of any axis.

3. Click OK when done selecting new quantities.

Removing a Plot Quantity

1. Select the quantity to delete, and click Delete Quantity or press Delete.

Changing a Plot Quantity

1. Select the Formula cell of the desired quantity, then click the ellipsis button.
2. Select the desired register and click OK.

Changing the Order of the Plot Quantities

1. Select the quantity to move, and click Move Up or Move Down or press Ctrl+Up

or Ctrl+Down.

Customizing Plot Quantities

Filter
You can choose to filter a plot quantity. This is most useful for the Actual Velocity and

Actual Acceleration, which tend to be noisy. To choose a filter, select Filter On in the

Filter cell of the desired Plot Quantity.
Number Format
You can set the number of decimal places for plotted quantities of REAL type:

deltamotion.com