RMC70/150 and RMCTools User Manual

a. In Channel 0:

Choose SSI Output mode.

Set the SSI Output Mode to Slave.

In the Source of Output Data section, choose the register that

contains the data to be sent. Typically this is a variable.

Set the SSI Data Bits to 32.

b. In Channel 1:

Choose SSI Register Input mode

Set the SSI Input Mode to Standard

Set the SSI Termination to ±Data.

In the Location to store SSI Data section, choose the register where

the received data will be stored. This must be a variable.

Set the SSI Data Bits to 32.

2. Configure the UI/O on the second RMC as follows:

a. In Channel 0:

Choose SSI Register Input mode

Set the SSI Input Mode to Standard

Set the SSI Termination to ±Data.

In the Location to store SSI Data section, choose the register where

the received data will be stored. This must be a variable.

Set the SSI Data Bits to 32.

b. In Channel 1:

Choose SSI Output mode

Set the SSI Output Mode to Slave.

In the Source of Output Data section, choose the register that

contains the data to be sent. Typically this is a variable.

Set the SSI Data Bits to 32.

3. Wire Channel 0 on the first RMC to Channel 0 on the second RMC as shown in RMC150

UI/O Wiring. Wire Channel 1 on the first RMC to Channel 1 on the second RMC.

4. Click OK.
5. The RMCs will automatically send data back and forth to each other.

7.3.11. PROFIBUS Module

7.3.11.1. PROFIBUS Module (RMC150)

The PROFIBUS module for the RMC150 provides PROFIBUS communications. Notice that since

the RMC150E CPU has built-in Ethernet, it is possible to communicate via Ethernet and

PROFIBUS simultaneously.
For details on setting up and using PROFIBUS, see the PROFIBUS Overview topic.

Features

PROFIBUS-DP

1 Comm Status LED

Standard PROFIBUS-DP DB-9 Connector