Delta RMC151 User Manual
Page 145
3 Controller Features
Note: This is very tedious to do directly from RMCTools, but you may need to when you are
first trying it.
Part #1:
Variable Data
Description
Curve Data
Offset
512 0
Status = 0
-
513 20
Format = 20
-
514 0
Part Offset = 0
-
515 507
Part Length = 507
-
516 2504
Total Length = 2504
-
517 2500
Point Count = 2500
0
518 0
Interpolation Options
= 0
1
519 0
X
0
= 0
2
520 0.1
X interval = 0.1
3
521 Y
0
Y
0
4
522 Y
1
Y
1
5
: :
:
:
1023 Y
502
Y
502
506
After writing part #1 and issuing the Curve Add command, the user should wait for the
Curve Status at Variable 512 to become 2 (if you are looking in RMCTools, make sure to
look in the Monitor tab of the Variable Table Editor), indicating that the RMC has
completed processing the part.
Part #2
Variable Data
Description
Curve Data
Offset
512 0
Status = 0
-
513 20
Format = 20
-
514 507
Part Offset = 507
-
515 507
Part Length = 507
-
516 2504
Total Length = 2504
-
517 Y
503
Y
503
507
: :
:
:
1023 Y
1009
Y
1009
1013
After writing part #2 and issuing the Curve Add command, the user should wait for the
Curve Status at Variable 512 to become 2 (if you are looking in RMCTools, make sure to
look in the Monitor tab of the Variable Table Editor), indicating that the RMC has
completed processing the part.
Part #3
Variable Data
Description
Curve Data
Offset
512 0
Status = 0
-
513 20
Format = 20
-
deltamotion.com