beautypg.com

Delta RMC151 User Manual

Page 145

background image

3 Controller Features

Note: This is very tedious to do directly from RMCTools, but you may need to when you are

first trying it.


Part #1:

Variable Data

Description

Curve Data

Offset

512 0

Status = 0

-

513 20

Format = 20

-

514 0

Part Offset = 0

-

515 507

Part Length = 507

-

516 2504

Total Length = 2504

-

517 2500

Point Count = 2500

0

518 0

Interpolation Options

= 0

1

519 0

X

0

= 0

2

520 0.1

X interval = 0.1

3

521 Y

0

Y

0

4

522 Y

1

Y

1

5

: :

:

:

1023 Y

502

Y

502

506

After writing part #1 and issuing the Curve Add command, the user should wait for the

Curve Status at Variable 512 to become 2 (if you are looking in RMCTools, make sure to

look in the Monitor tab of the Variable Table Editor), indicating that the RMC has

completed processing the part.
Part #2

Variable Data

Description

Curve Data

Offset

512 0

Status = 0

-

513 20

Format = 20

-

514 507

Part Offset = 507

-

515 507

Part Length = 507

-

516 2504

Total Length = 2504

-

517 Y

503

Y

503

507

: :

:

:

1023 Y

1009

Y

1009

1013


After writing part #2 and issuing the Curve Add command, the user should wait for the

Curve Status at Variable 512 to become 2 (if you are looking in RMCTools, make sure to

look in the Monitor tab of the Variable Table Editor), indicating that the RMC has

completed processing the part.
Part #3

Variable Data

Description

Curve Data

Offset

512 0

Status = 0

-

513 20

Format = 20

-

deltamotion.com

125

This manual is related to the following products: