beautypg.com

Delta RMC151 User Manual

Page 1155

background image

10 Wiring and Installation

Pin

Function

Int/Clk + SSI + Clock
Int/Clk - SSI - Clock
Cmn

Common

Ret/Dat + SSI + Data
Ret/Dat - SSI - Data
Case

RMC70 Chassis

Max Cable Length

SSI Clock Rate

Maximum Cable Length*

100 kHz

2100 ft (640 m)

150 kHz

1360 ft (415 m)

250 kHz

770 ft (235 m)

375 kHz

475 ft (145 m)

* The cable lengths are approximate, and may be affected by the type of wire and

transducer.

Wiring Instructions

Connect both the +Clock and -Clock between the MA module and transducer for the

clock signal.

Connect both the +Data and -Data between the MA module and transducer for the

data signal.

Connect the transducer DC ground to Cmn. Each axis has two Cmn pins. Either of the

2 pins may be used. The Cmn must be connected to the transducer, or the signals will

not be read correctly!

The transducer power supply is not provided by the RMC. The user must supply a

power supply. The power supply common may be connected to the same common that

is connected to the RMC70 CPU Cmn.

Diagram


deltamotion.com

1135