6 Communication

Communicating with the RMC75E and RMC150E from other devices will use one of the

following four methods. Review each to determine which is appropriate for your device:

PLC Ethernet Emulation

The RMC responds to several common industrial Ethernet protocols and can emulate,

or act like, several common PLCs. If your device supports reading and writing to

registers in any of these PLCs, then your device should be able to communicate with

the RMC. See Using the RMC’s PLC Ethernet Emulation for details.

Standard Industrial Ethernet Protocols

The RMC75E and RMC150E controllers support several common industrial Ethernet

protocols, including Modbus/TCP, PROFINET and EtherNet/IP. If your device can make

requests in any of the RMC’s supported industrial Ethernet protocols, then it can likely

communicate with the RMC. See the Supported Ethernet Protocols section in the

Ethernet Overview topic for details.

ActiveX Control or .NET Assembly

Applications that are running on a Windows PC and that support ActiveX Controls,

.NET Assemblies, or Microsoft Component Object Model (COM) can use Delta’s

RMCLink ActiveX Control and .NET Assembly. See the RMCLink topic for details.

Direct over TCP or UDP

Third-party or custom controllers that do not support any of the above three methods

but can send and receive either TCP or UDP packets directly can communicate with the

RMC by manually building and parsing Procedure Exist packets over TCP or FINS/UDP

packets over UDP. See the Communicating Directly over TCP and Communicating

Directly over UDP topics for details.

Serial RS-232 and RS-485

The RMC75S supports serial RS-232 and RS-485. The RMC150 does not support serial

communication, but can communicate with serial devices via serial-to Ethernet converters

sold by other manufacturers. Contact Delta for more information.
Communicating with the RMC from serial devices will use one of the following methods.

Review each to determine which is appropriate for your device:

Standard Industrial Ethernet Protocols

The RMC75S supports the several industrial serial protocols, including Modbus RTU,

DF1, and the Mitsubishi Bidirectional Protocol. For details, see each respective topic.

ActiveX Control or .NET Assembly

Applications that are running on a Windows PC and that support ActiveX Controls,

.NET Assemblies, or Microsoft Component Object Model (COM) can use Delta’s

RMCLink ActiveX Control and .NET Assembly. See the RMCLink topic for details.

PROFIBUS-DP

The RMC75P and RMC150 can communicate via PROFIBUS-DP. For details, see the

PROFIBUS topic.