9 Register Reference

8-

11

Axis 0-3 bits,

if all zero,

then use

Axis Owner

12-

23

Reserved

F36:6

18445

D18444 REAL

%MD36.6

-

-

Reserved

F36:7

18447

D18446 REAL

%MD36.7

-

-

Reserved

F36:8

18449

D18448 REAL

%MD36.8 REAL

Read Only Plot ID

F36:9

18451

D18450 REAL

%MD36.9 REAL

Read Only Plot State

0 = not triggered, 1

= capturing, 2 =

complete

F36:10

18453

D18452 REAL

%MD36.10 DINT

Read Only Plot Captured

Samples
Number of plot

samples captured.

Only applies for Plot

State > 0.

F36:11

18455

D18454 REAL

%MD36.11 DINT

Read Only Plot Sample 0 Time

Time that first plot

sample was

captured. In control

loops since

controller startup

(low 24 bits). Only

applies for Plot

State > 0.

F36:12

18457

D18456 REAL

%MD36.12 DINT

Read Only Plot Trigger Time

Time that plot

trigger occurred. In

control loops since

controller startup

(low 24 bits). Only

applies for Plot

State > 0.

F36:13

18459

D18458 REAL

%MD36.13 DINT

Read Only Plot Trigger Index

Index of the plot

sample at which the

plot trigger

occurred. Only

applies for Plot

State > 0.

F36:14-

15

18461-

18463

D18460-
D18462

-

%MD36.14-

15

-

-

Reserved

F36:16-

31

18465-

18495

D18464-
D18494

REAL

%MD36.16-

31

DWORD Read/Write Plot Data Sets 0-15

Addresses
Files %MDn:16-31

contain the

Addresses for plot

deltamotion.com

1079