Delta RMC151 User Manual
Page 1099
9 Register Reference
8-
11
Axis 0-3 bits,
if all zero,
then use
Axis Owner
12-
23
Reserved
F36:6
18445
D18444 REAL
%MD36.6
-
-
Reserved
F36:7
18447
D18446 REAL
%MD36.7
-
-
Reserved
F36:8
18449
D18448 REAL
%MD36.8 REAL
Read Only Plot ID
F36:9
18451
D18450 REAL
%MD36.9 REAL
Read Only Plot State
0 = not triggered, 1
= capturing, 2 =
complete
F36:10
18453
D18452 REAL
%MD36.10 DINT
Read Only Plot Captured
Samples
Number of plot
samples captured.
Only applies for Plot
State > 0.
F36:11
18455
D18454 REAL
%MD36.11 DINT
Read Only Plot Sample 0 Time
Time that first plot
sample was
captured. In control
loops since
controller startup
(low 24 bits). Only
applies for Plot
State > 0.
F36:12
18457
D18456 REAL
%MD36.12 DINT
Read Only Plot Trigger Time
Time that plot
trigger occurred. In
control loops since
controller startup
(low 24 bits). Only
applies for Plot
State > 0.
F36:13
18459
D18458 REAL
%MD36.13 DINT
Read Only Plot Trigger Index
Index of the plot
sample at which the
plot trigger
occurred. Only
applies for Plot
State > 0.
F36:14-
15
18461-
18463
D18460-
D18462
-
%MD36.14-
15
-
-
Reserved
F36:16-
31
18465-
18495
D18464-
D18494
REAL
%MD36.16-
31
DWORD Read/Write Plot Data Sets 0-15
Addresses
Files %MDn:16-31
contain the
Addresses for plot
deltamotion.com
1079