6 Communication
Input Tag
Set
Leave this set to the default, Output_2 –
[44Byte] in this example.
Connection
Type
Select Point to Point connection.
Packet
Interval (RPI)
Select the desired update rate. A commonly
used RPI is 20.0 ms. Very low RPIs may flood
the network, and reduce network reliability.
Timeout Value Select Packet Interval (RPI) x 4, although for
the minimum RPI of 2.0 ms, the Omron only
supports Packet Interval (RPI) x 8 or higher.
Connection
Name
Optionally assign a user-readable name for this
connection.
e.
Click Regist.
f.
If prompted to add another connection, click Close. The Connections tab should
now look like this:
10.
Add additional RMC75/150 devices to your EtherNet/IP network.
a.
Repeat steps 6-9 above for each additional RMC75/150 device.
11.
Download the Network Configuration
a.
On the Option menu, point to Select Interface, and then click Ethernet I/P.