beautypg.com

Md45.6, F45:6, Communication configuration – Delta RMC151 User Manual

Page 1126

background image

RMC70/150 and RMCTools User Manual

F44:8

22545

D22544 REAL

%MD44.8 DINT

Read/Write Startup Mode

0=PROGRAM, 1-RUN

(default = 0)

F44:9

22547

D22546 REAL

%MD44.9 DINT

Read/Write RUN/PROGRAM

Input
0 = None
1 = %IX1.0 (CPU

input 0)
2 = %IX1.1 (CPU

input 1)

F44:10 22549

D22548 REAL

%MD44.10 REAL

Read Only Time

The _Time register

wraps every second

through the range

[0.000000,

1.000000). It can be

used as a master for

Curves that are to

run based on time.

F44:11-

31

22551-
22591

D22550-

D22590

-

%MD44.11-

31

-

-

Reserved

RMC150 Registers, File 45: Communication Configuration

AB
DF1,
CSP

Address

Modbus

TCP,RTU

Address

FINS
Address

External
Data

Type

Internal
I
EC

Address

Internal

Data

Type

Access

Register Name

F45:0-3 23041-

23047

D23040-

D23046

-

%MD45.0-3 -

-

Reserved

F45:4

23049

D23048 REAL

%MD45.4 DINT

Read/Write PROFIBUS: Station

Address
Indicates the current

PROFIBUS station

address for this

controller. Valid

values are 1 to 126.

The default is 126,

which is reserved for

unaddressed

PROFIBUS devices.

NOTE: Only

RMC150E controllers

with the PROFIBUS

communication

module installed

have this register.

F45:5

23051

D23050 REAL

%MD45.5 DINT

Read/Write PROFIBUS: Lock

Address
0=unlocked,

1=locked

1106

Delta Computer Systems, Inc.

This manual is related to the following products: