8 Command Reference

Frequency (2)

Cycles (3)

2 New Value

Depends on

selected

Parameter

3 Ramp Type

Time (0)

Cycles (1)

Rate (2)

Time (log) (3)

Cycles (log) (4)

A valid integer as

described

4 Ramp Value

Depends on

selected Ramp

Type

Description

This command changes a target parameter for certain types of position moves that are in

progress. For example, this command can be used to perform frequency sweeps by

ramping the frequency of a sine move in a certain amount of time. For pressure or force,

see the Change Target Parameter (Prs/Frc) (81) command.
Target parameters can be ramped independently of each other. That is, each parameter

can be ramped whether or not other parameters are ramping. Multiple Change Target

Parameter commands can be issued from a single step in a user program, allowing them

to be ramped together.
This command applies to motion started by the following commands:

Sine Start (72)

Sine Start Parameters

When this command is used for changing target parameters of motion started with a Sine

Start (72) command, the following parameters can be changed:
Offset
When ramping the offset, there will be a discontinuity in the velocity at the beginning and

end of the ramp. This can cause the axis to jump.

Valid Ramp

Types

Time

Ramp the Offset linearly in the number of seconds specified by the

Ramp Value.

Cycles

Ramp the Offset linearly in the number of cycles specified by the

Ramp Value.

Rate

Ramp the Offset linearly at the rate (units/sec) specified by the

Ramp Value.

Amplitude
The amplitude can be ramped to any positive value, or zero.

Valid Ramp

Types

Time

Ramp the Amplitude linearly in the number of seconds specified by

the Ramp Value.

Cycles

Ramp the Amplitude linearly in the number of cycles specified by the

deltamotion.com

763

This manual is related to the following products: