Negative limit input, As a negative limit input – Delta RMC151 User Manual

Page 941

background image

9 Register Reference

modules only. This is the PosLim input on the

module.

general

input

RMC70: any input from a D8 module, but only from

the first 12 I/O points as listed in the I/O Monitor.
RMC150: any general discrete input from any

module.

Positive Limit Format Details

This section is primarily for addressing the Positive Limit Input parameter when

communicating with the RMC from an external device. This information is not necessary

when configuring the Positive Limit Input in RMCTools.
The Positive Limit Input is selected with bits in the Primary Input Bits register, as shown

in the following table:

RMC70

Value

of
bits 4-

7

Positive Limit Input

0

none

1

Fault Input

2

Dedicated

(RegX/PosLim)

3

-

4

%IX0

5

%IX1

6

%IX2

7

%IX3

8

%IX4

9

%IX5

10

%IX6

11

%IX7

12

%IX8

13

%IX9

14

%IX10

15

%IX11

RMC150

Value of bits 8-15

Positive

Limit Input

0

none

1

Fault Input

2

Dedicated

(RegX/PosLim)

3

-

(32 x slot) + (i/o point)

+ 4

%IXslot.(i/o

point)


The slot numbering starts with 0 for the

left-most module in the RMC150.
The I/O Monitor also displays the slot

number and I/O number of each I/O point.

For example, the I/O point 4 in slot 3 is

displayed as 3.4.

For example, input 4 in slot 0 is:

(32 x 0) + (4) + 4 = 8


For example, input 7 in slot 5 is:

(32 x 5) + (7) + 4 = 171


See the Primary Input Bits Register for details about the register containing the Positive

Limit Input bit.

9.2.2.2.22.2. Negative Limit Input

Type: Axis Parameter Register Bit Parameter

RMC70 Address: %MDn.9/8-11, where n = 12 + the axis number

RMC150 Address: %MDn.9/16-23, where n = 24 + the axis number

deltamotion.com

921