beautypg.com

Quadrature (q) module (rmc150), 150 quad, Quad – Delta RMC151 User Manual

Page 681: Quad), Quadrature module, 150 quadrature, Quadrature (q) module, Quad (q)

background image

7 Hardware

7.3.7.1. Quadrature (Q) Module (RMC150)

The Quadrature module for the RMC150 interfaces to RS-422 quadrature feedback devices,

both rotary encoders and linear transducers. The Quad module allows cost effective control of

a wide variety of electric drives as well as electric and hydraulic servo motors.
The 2-axis Quad module generates analog control outputs and interfaces to quadrature

encoders with 5V RS-422 differential signals. Additional high-speed inputs allow for homing,

registration, or positive and negative limits on a per axis basis.
See the Quadrature Fundamentals topic for details on how quadrature feedback works.

Features

Two axes of 5 V RS-422 differential quadrature feedback per module

Phase A and B (A, A, B, B)

Index Z (Z, Z)

4,000,000 counts/second maximum

High-speed dedicated Home position input

50 µs response to home input

Positive and negative travel limit inputs

Digital noise filters on all inputs

Status LEDs

Two isolated, ±10 V, 14-bit control outputs per module

Current output up to ±200 mA with VC2124 converter option

1 Fault input per axis

1 Enable output per axis

2 Inputs per axis for Travel Limits or Registration Inputs

All discrete inputs are isolated

Part Number

The part number of the MDT module is Qn, where n is the number of Quad modules.
For example, RMC150E-Q1 is an RMC150E with one Quad module. RMC150E-Q3-H1 is an

RMC150E with three Quad modules and one Analog H module.

Setting Up the Quad Module

To set up the Quad module, read the following topics:
Quad Wiring
Quadrature Scaling

Specifications

For general specifications on the RMC150, see the RMC150 Overview topic.

Quadrature Interface

Encoder Inputs 5 V RS-422 differential receiver

Quadrature A, B, Z

Input Impedance 215 Ω termination

Max. Encoder Frequency 4,000,000 quadrature counts/second

ESD Protection 15 kV

RegX/PosLim, RegY/NegLim, Home and Fault Inputs

Input Characteristics 5-24 VDC, sinking (sourcing driver)

deltamotion.com

661

This manual is related to the following products: