Max wiring, Max wiring 3, Ma wiring – Delta RMC151 User Manual
Page 1153
10 Wiring and Installation
10.2.6. MAx Wiring
The MAx module can be wired to MDT and SSI transducers. Each axis on the MAx also has a
Fault input, Enable output, and a Control output. If the MA module has two axes, each axis'
pinout is identical.
Use shielded twisted pairs for all connections to inputs and outputs. Route the transducer
wiring separate from other wiring. You must provide the power supplies needed by your
transducers. See Wiring Guidelines for general wiring information.
Wire clamp screws must be tightened to max 7 b-in (0.8Nm).
NOTE:
The following example schematics do not include transducer pin numbers, color codes, or
power supply requirements, since these vary between different transducers. To determine
your power supply needs and connector pin-outs or cable color codes, consult your transducer
manufacturer's documentation.
Pin-Out
Pin
#
MA1 Label
MA2 Label
Function
1
+Fault In
Flt In+
Fault Input
2
-Fault In
Flt In-
3
+Enable Out
En Out+
Enable Output
4
-Enable Out
En Out-
5
Control Out
Ctrl Out
Control Output
6
Common
Cmn
Common
7
+Int/Clock
Int/Clk+
MDT Interrogation or SSI Clock
8
-Int/Clock
Int/Clk-
9
Common
Cmn
Common
10
+Ret/Data
Ret/Dat+
MDT Return or SSI Data
deltamotion.com
1133