6

Common

Cmn

Common

7

+Analog In

An In+

+Analog Input

8

Jumper for 4-

20mA

Jmpr for 4-

20mA

Jumper for 4-20mAfeedback

9

-Analog In

An In

-Analog In

10

Common

Cmn

Common

11

+10Vdc Exciter

Out

+10Vdc

Exciter

+10Vdc output for potentiometers

12

Case

Case

Connected to

The commons are internally connected.

Voltage Feedback Transducers

Voltage feedback transducers can be connected directly to the Input + and Input -

connections of the desired axis. The Cmn must be connected to the transducer, or the

signal will not be read correctly! The following configuration is recommended:

Current Feedback Transducers

Current feedback transducers are connected in the same way as voltage transducers

except that a jumper must be inserted between the Input+ and Jumper for 4-20 mA

pins. The label indicates where this jumper should be connected. This places a resistor

internal to the RMC across the two inputs, thus converting the current to a voltage input.

The wiring diagram below shows a suggested configuration.
The Cmn must be connected to the transducer, or the signal will not be read correctly!

2-Wire Current Transducer

1132