RMC70/150 and RMCTools User Manual

7

Float*

Explicit Write Value


*These registers are typically REAL data type (floating point), but in some cases may be

DINT or DWORD integers, such as variables declared as such.

Response Block
The Response Block is a block of 16 contiguous 32-bit input registers (cyclic read

registers), corresponding to the Indirect Data Map registers 0 to 15 in the RMC70. These

registers are continuously sent from the RMC70 to the PLC or PC. See Configuring the

Data below for details on setting up this data.
Each of the 16 contiguous input registers always reads from the same Indirect Data Map

register in the RMC70, as listed in the Description column below. However, one of the

registers in the Response Block can be set up to return the value of a read from any

single register in the RMC70. This allows you to read the value of any single register at

any time. See Read from the RMC70 below.
The Response Block has the following structure:

Register
Number

Data
Type


Description

0

Integer

Indirect Data 0 - must be Axis 0 Status bits!

Bit

Bit Description

31

Command Acknowledge

30

Read/Write Acknowledge

0-29 Axis 0 Status Bits

1

Float*

Indirect Data 1

2

Float*

Indirect Data 2

3

Float*

Indirect Data 3

4

Float*

Indirect Data 4

5

Float*

Indirect Data 5

6

Float*

Indirect Data 6

7

Float*

Indirect Data 7

Note:

Registers 8-15 are not consistent with registers 0-7. See explanation below.

8

Float*

Indirect Data 8

9

Float*

Indirect Data 9

10

Float*

Indirect Data 10

11

Float*

Indirect Data 11

12

Float*

Indirect Data 12

13

Float*

Indirect Data 13

14

Float*

Indirect Data 14

15

Float*

Indirect Data 15

*These registers are typically REAL data type (floating point), but in some cases may be

DINT or DWORD integers, such as variables declared as such.
A Note about PROFIBUS Consistency

502

Delta Computer Systems, Inc.