9 Register Reference


This register

controls whether the

PROFIBUS Station

Address can be

changed over

PROFIBUS by a

Class 2 master.

Notice that

RMCTools can

always change the

station address,

regardless of the

value of this

register. Also,

setting the station

address over

RMCTools will set

this register to zero

(0).

NOTE: Only

RMC150E controllers

with the PROFIBUS

communication

module installed

have this register.

F45:6

23053

D23052 DWORD %MD45.6 DWORD Read Only PROFIBUS

Connection Status

F45:7

23055

D23054 DINT

%MD45.7 -

-

Reserved

F45:8

23057

D23056 DWORD %MD45.8 DWORD Read Only MAC Address (bytes

0-3)
big Endian, (for 00-

50-A0-B1-23-45,

this would be

0x0050A0B1)

F45:9

23059

D23058 DWORD %MD45.9 DWORD Read Only MAC Address (bytes

4-5)
big Endian, in upper

16 bits (for 00-50-

A0-B1-23-45, this

would be

0x23450000)

F45:10 23061

D23060 DWORD %MD45.10 DWORD Read Only Ethernet Status Bits

F45:11 23063

D23062 DWORD %MD45.11 DWORD Read/Write Ethernet

Configuration Bits

F45:12 23065

D23064 DWORD %MD45.12 DWORD Read/Write IP Address

F45:13 23067

D23066 DWORD %MD45.13 DWORD Read/Write Subnet Mask (0=use

standard network

masks)

F45:14 23069

D23068 DWORD %MD45.14 DWORD Read/Write Default Gateway

(0=none)

F45:15 23071

D23070 DWORD %MD45.15 DWORD Read Only DHCP (or BOOTP)