If the axis is already retracted, the Home Input status will already be ON and the

axis needs only extend as described above. When the axis is shut down, it should

be retracted until the Home Input status bit is ON. This way the axis need only

extend a small amount to be homed on startup.

Disarm Home
To disarm the home manually, use the Disarm Home (51) command.

Explicit Homing

The following command set adjusts the axis position without needing a Home or Z input:

Offset Position (47)

This command adds the requested Position Change to the Actual, Target, and

Command Positions.

Set Target Position (48)

This command sets the Target Position to the requested Position, and adjusts the

Command Position, and Actual Position by the same amount as the Target Position

changed.

Set Actual Position (49)

This command sets the Actual Position to the requested Position, and adjusts the

Command Position and Target Position by the same amount as the Actual Position

changed.

Why Bother?
Explicit homing is useful when the operator physically measures something on the

machine and needs to make an adjustment to the positions.
Explicit homing can de done on any axis type, not just those with incremental feedback.

Homing SSI and Resolver Axes

SSI and Resolver axes give absolute positions, and therefore, homing them is not

necessary. In certain applications, these axes types can be set up as incremental, and

can be homed.
SSI and Resolver Homing Trigger Types
The following trigger types are available on SSI and Resolver axes. The axis must be set

to incremental.

#

Trigger

Type

Description

Valid for

RMC70

RMC150

0 H Rising

Trigger a Home on the rising edge of the Home Input.

SSI*

1 H Falling

Trigger a Home on the falling edge of the Home Input.

SSI*

2 Z

Trigger a Home on the Index (Z) Input.

SSI*

SSI*, Resolver*

3 Z And H

Trigger a Home on the Index (Z) Input if the Home Input

is high.

SSI*

4 Z And Not

H

Trigger a Home on the Index (Z) Input if the Home Input

is low.

SSI*

5 Absolute

Adjust

(H Rising)

On the rising edge of the Home Input, the zero Raw

Counts point of the SSI encoder is set to the requested

Home Position.

SSI*

6 Absolute

Adjust

(H Falling)

On the falling edge of the Home Input, the zero Raw

Counts point of the SSI encoder is set to the requested

Home Position.

SSI*

7 Absolute

Adjust

(Immed)

The zero count point of the SSI encoder is set to the

requested Home Position immediately when this

command is issued.

SSI*

SSI*, Resolver*

58

Delta Computer Systems, Inc.

This manual is related to the following products: