Data Channel 0 Logging

For the Basic/Enhanced modes, logs the specified actions

from Data Channel 0.
None: Do not log any actions from Data Channel 0.
Requests: Log only read or write requests from Data

Channel 0.
All: Log every change in the Data Channel 0 data.

Data Channel 1 Logging

For the Basic/Enhanced modes, logs the specified actions

from Data Channel 1 (available only in Enhanced RMC

PROFIBUS modes).
None: Do not log any actions from Data Channel 1.
Requests: Log only read or write requests from Data

Channel 1.
All: Log every change in the Data Channel 1 data.

I/O Mode Data Logging

For the I/O modes, logs the PROFIBUS Output Data

(coming from the PLC to the RMC) each time there is a

change in the data.

Configuration Information

Logs PROFIBUS initialization state changes and

configuration and parameterization information received

from the PROFIBUS master.


4.16. General Tools

4.16.1. Uploading and Downloading

Downloading transfers data from RMCTools to the RMC controller.
Uploading transfers data from the RMC controller to RMCTools.
Note:

RMCTools must be online in order to upload or download.

Note:

When downloading, the new data will write over the existing RMC data. However, it will not be

saved in Flash until you update Flash.

Instructions

In general, items in the Project pane can be uploaded or downloaded by right-clicking and

choosing Upload from Controller or Download to Controller. In many editor

windows, the window contents can be uploaded or downloaded by clicking the download
button or the upload button . Uploading and downloading can also be accessed from

the Controller, Programming and Editor menus.

Item

Location of Download/Upload

All project contents

In the project pane, right-click the controller.

Axis Parameters

In Axis Tools window toolbar.

Programming (includes Variables (not

Current Values), Discrete I/O

Configuration, Program Triggers, User

In the project pane, right-click the

Programming folder.

254

Delta Computer Systems, Inc.

This manual is related to the following products: