RMC70/150 and RMCTools User Manual

Data Type: REAL

Units: Pr or Fr

Range: any

Default Value: 0

Description

The Pressure Offset or Force Offset parameter is used together with the Pressure Scale or

Force Scale parameter to calculate the Actual Force or Actual Pressure from the voltage or

current of the input.
The Offset is added to the scaled Pressure or Force.
Changing this Parameter
Because this parameter affects motion, the axis must be disabled or in Direct Output

before writing to this parameter. The Enabled and Direct Output Status Bits indicate these

states of the axis. When changing this parameter from RMCTools, the software will

automatically do this for you. This may cause a halt on the axis, which is expected.

9.2.2.2.22. Limit Inputs

9.2.2.2.22.1. Positive Limit Input

Type: Axis Parameter Register Bit Parameter

RMC70 Address: %MDn.9/4-7, where n = 12 + the axis number

RMC150 Address: %MDn.9/8-15, where n = 24 + the axis number

System Tag: _Axis[n].PriInputBits.PosLimIn

How to Find: Axes Parameters Pane, All tab: Feedback

Data Type: bits

Default Value: 0 (none)

Description

Each RMC axis allows for optional physical limit inputs to specify the boundaries in which

the axis is allowed to operate. Each axis can have two physical limit inputs: Positive Limit

Input and Negative Limit Input. Typically, these inputs are wired to limit switches.
The physical limit inputs differ from the Travel Limits, which limit the range of travel of an

axis based on the feedback (position, pressure, etc.). The Travel Limits are required to be

set on an axis; physical limit inputs are optional.
The Positive Limit Input bit parameter selects which discrete input, if any, should be used

as a 'Positive Limit Input'. For details on the operation of the physical limit inputs, see the

Physical Limit Inputs topic.
In RMCTools, this parameter will allow you choose an input from the drop-down box.

Inputs will be listed by their address. Use the Discrete I/O Configuration editor to find the

addresses of inputs.
The following options are possible:

Option

Description

none

This is the default setting.

Fault

Input

RMC70: The Fault Input of the axis.
RMC150: The Fault Input of the axis. Only available

on the Quadrature Module.

Dedicated Available on RMC70 QA and RMC150 Quadrature

920

Delta Computer Systems, Inc.