o

Right-click on the RMC slave device icon, and click Configure from the

shortcut menu.

o

In the Configure: Delta RMC Family dialog, click Order No.

o

In the Select by Order Number dialog, click the order number

determined in the previous steps. Click Accept. Click Close.

Click OK.

6. You may wish to assign register addresses within the master at this time.

This is optional for many masters, because it can be done in the master configuration

software. In fact, at times it is not possible to edit the register addresses.

Right-click on the RMC slave device icon, and select Configure from the shortcut

menu.

Move the cursor to the top row's I Addr cell, and either enter the offset that you

wish to access the data at, or click the Auto Addr. button. Do the same for the O

Addr cell.

Click OK.

7. Select the data word order.

Because PROFIBUS-DP does not specify the word order for 32-bit values, we allow the

order to be swapped. You will probably not know which is correct until later in the

process. If you receive data over the PROFIBUS network, but the values are not what you

expect or do not make sense, return to this step and try swapping the word order:

Right-click the RMC slave device icon and click Parameterize.

Select the cell in the Value column for the Word Order parameter.

Click Select.

Choose LSW First or MSW First, and click OK.

8. Add any other RMC devices you want on the same network. To do this, repeat steps 5, 6

and 7.

9. Save your configuration.
10. Send the configuration to the master device. This step varies greatly depending on the

type of master you use.

6.9.3.3. Configuring a PROFIBUS-DP Network with SST

Profibus Configuration

Before reading this topic, you should read and understand PROFIBUS Configuration. This topic

only gives a specific example of doing one step of the configuration process. In addition, SST

may, and probably will, change the steps taken here slightly with each version of SST Profibus

Configuration.

The following steps have been tested with SST Profibus Configuration versions 1.9.9:

1. Start SST Profibus Configuration.
2. If you are modifying an existing PROFIBUS-DP network, open your current configuration

file.

3. If you are creating a new PROFIBUS-DP network, you must create a new network and add

a master device to the network:

On the File menu, click New.

The tree-type control on the left is the GSD library. It contains all devices known

about. In this tree, expand Masters and SST and double-click on the SST master

you will be using (e.g. SST-PFB-SLC).