3 Controller Features

Curve Start (Prs/Frc) (87)

Curve Start Advanced (Prs/Frc) (89)

Exiting Pressure or Force Control

To exit pressure/force control, issue the Open Loop Rate (10) or Direct Output (9)

command. An Open Loop Halt or Direct Output Halt will also cause the axis to exit

pressure/force control.

Pressure/Force Limit

Pressure/Force Limit can be used on a pressure-only or force-only axis, although it is

typically not very useful. Pressure/force limit is most useful on axes that also have

position or velocity feedback. On pressure/force axes, pressure/force limit can only limit

the pressure/force while moving the axis with the Open Loop Rate (10) command.
For example, consider an axis on which force limit is enabled. If the is moving with an

open loop Control Output of 2 volts, and the Target Force is 300 lbs, the axis will move

with 2 volts Control Output until the Actual Force reaches 300 lbs. Then, the Control

Output will be limited so that the force will not exceed 300 lbs.
Notice that with a large open loop voltage, a pressure/force limited axis will behave

similarly to an axis in pressure/force control. That is, the pressure/force can be controlled

very accurately, even with the specialty pressure/force commands, such as a sine wave

(using the Sine Start (Prs/Frc) (76) command) or a cam (using the Curve Start (Prs/Frc)

(87) command).
Pressure/force limit cannot be used simultaneously with pressure/force control. If the axis

is in pressure/force limit, and a command is issued that puts the axis in pressure/force

control, the pressure/force limit will no longer be active and the axis will start controlling

the pressure/force. However, the Pressure/Force Limit Enabled status bit will still be set,

and if the axis exits pressure/force control, it will resume pressure/force limit.

Pressure/Force Control Status Bits

The following status bits give the status of the pressure/force control. These tell you what

the control is doing, and can also be very useful in user programs.
At Pressure/Force
When the axis is in Pressure/Force control or Pressure/Force Limit and the Target

Pressure/Force reaches the Requested Pressure/Force and the Actual Pressure/Force

is within the At Pressure/Force Tolerance window from the Target Pressure/Force, the At

Pressure/Force Status bit will be set. This bit indicates that the ramp is complete and the

axis is at the pressure/force.
Pressure/Force Control
The Pressure/Force Control Status bit indicates that the axis is in closed-loop

pressure/force control.
Pressure/Force Limit Enabled
This bit indicates that pressure/force limit is enabled. If an axis is in pressure/force

control, pressure/force limit will not be active. If the axis exits pressure/force control to

open loop or closed-loop position or velocity control, it will enter pressure/force limit if the

Pressure/Force Limit Enabled bit is on.
Pressure/Force Limited
This bit indicates that pressure/force limit is enabled and the axis is limiting the

pressure/force. If an axis is in pressure/force control, pressure/force limit will not be

active and this bit will not be set.
Pressure/Force Target Generator Bits

The Pressure/Force Target Generator bits in the Status Bits register indicate which

portion of the move the axis is currently in. These bits are useful when programming

complex motion sequences.