beautypg.com

Rmc70 part numbering – Delta RMC151 User Manual

Page 640

background image

RMC70/150 and RMCTools User Manual

with 4 Expansion modules Varies, 2.0 lb (0.9 kg) max

Environment

Operating temperature +32 to +140°F (0 to +60°C)

Storage temperature -40 to +185°F (-40 to +85°C)

Humidity 95% non-condensing

Agency compliance UL, CUL, CE: RMC75S, RMC75P, RMC75E

7.2.2. RMC70 Part Numbering

Specify RMC70 part numbers when ordering and when contacting Delta customer support.

Part Numbering Schema

Base Unit

Optional

Expansion

Modules*

RMC70

Series

CPU

Axis

Module

RMC7NXXX - XXN

EXP70-

XXXN

Choices

Choices

Choices

RMC75E

RMC75S

RMC75P

AA1
AA2
MA1

MA2
QA1
QA2

A2
AP2

D8
Q1


*Up to four optional expansion modules can be added to enhance the capabilities of the

RMC70. These modules can be field-added. Expansion modules can be used for reference

axes, pressure control, or discrete I/O.
Example Part Numbers
RMC75E-AA2
RMC75S-MA2
EXP70-D8
EXP70-Q1

Definitions

Module

Description

CPUs

RMC75E

Controller with Ethernet Communications

RMC75S

Controller with Serial Communications

RMC75P

Controller with PROFIBUS-DP

Communications

Axis Modules

AA1

1-Axis Analog Voltage or Current Input,

620

Delta Computer Systems, Inc.